Configuration Backup
Although the system configuration will not change upon the software upgrade, creating a backup file of the configuration is mandatory by exportingthe complete configuration before any software upgrade.
...
The MCM-9000 software is delivered on a USB Flash disk (DoK). Besides , Online and Offline Software Upgrade, it is possible to do software upgrades through API.
To perform a Software upgrade along with a License and Firmware update or Firmware upgrade through API, follow the below steps:
1. Download Latest Files
Anchor |
---|
| step1 |
---|
| step1 |
---|
isMissingRequiredParameters | true |
---|
|
Login to TagVS Storage Center and download the latest files: "MCM-9000_vxxxx.rar" (software)
...
and "Firmware_vxxxx.rar" (firmware)
...
.
2. Upload Software to Device
...
Anchor |
---|
| step2 |
---|
| step2 |
---|
isMissingRequiredParameters | true |
---|
|
Use the POST following command to upload software to the GUI.
POST Resource URL : http://{host}/api/2.0/system_files/command/UploadFile/software
Please refer to API documentation here.
For Example, http://192.168.10.131/api/2.0/system_files/command/UploadFile/software
Under the body section on the POSTMAN, insert the KEY as data (File)[File][0], upload the MCM file to upgrade under the VALUE field as shown below, and click Send.
...
...
Expand |
---|
|
Code Block |
---|
| {
"Task": {
"id": 773281,
"device_id": 9898,
"type": "Software Ingest",
"type_id": 23,
"mode": "Starting",
"mode_id": 1,
"status": null,
"description": null,
"total": 0,
"completed": 0,
"time_remained": 0,
"modified": "1706159122746"
}
} |
|
3.
...
Select the next boot image
...
Anchor |
---|
| step3 |
---|
| step3 |
---|
isMissingRequiredParameters | true |
---|
|
Use the following command to GET “next_boot_image“ from the response.
GET Resouce URL : http://{host}/api/2.0/devices/9898{id}/.json
Please refer to API documentation here.
...
For example, http://192.168.10.131/api/2.0/devices/9898/.json
Response |
Code Block |
---|
| {
"Device": {
"id": 9898,
"is_conected_device": 1,
"title": "MCM9000-SN:9898",
"color": "#8f6ce0,#abd93f",
"sys_up_time": "1702843699579",
"sys_running_time": "2128004930",
"current_time": "1704971704509",
"stack_title": null,
"series": "MCM-9000 Series",
"model": "MCM-9000",
"serial": "9898",
"version": "6.3.5",
"hardware_desc": "Intel(R) Xeon(R) Gold 6140 CPU @ 2.30GHz (x16), 16 GB Ram",
"capability_desc": "88 Channels",
"license_sharing": 1,
"active_licenses": 5.6,
"total_licenses": 0,
"active_weight": 25,
"total_weight": 68,
"active_decoders": 5,
"active_recorders": 0,
"active_fingerprints": 3,
"active_descramblers": 0,
"active_uncompressed": 0,
"active_encoders": 0,
"working_mode_id": 1,
"current_active_image": 1,
"next_boot_image": 2,
"modified": "1704971704509",
"status_stack_title": null,
"ntp_offset": 177.411,
"ntp_offset_age": 5,
"ntp_drift": null,
"ntp_sync": 1,
"max_rec_time": 0,
"cur_rec_bandwidth": 0,
"status_id": 4,
"ip_address": "192.168.10.131",
"licensed_features": 254,
"license_expiration": null,
"Ldap": {
"enabled": 0,
"host": "",
"port": 389,
"version": 3,
"secured": 0,
"bindDN": "uid=test,ou=people,dc=testlab,dc=com",
"network_id": 0,
"bindPassword": "",
"baseSearchDN": "dc=testlab,dc=com",
"userLoginAttribute": "uid",
"userSearchFilter": "(objectClass=*)",
"groupMembershipAttribute": "memberuid",
"groupSearchDN": "cn=mcm9000,ou=group,dc=testlab,dc=com"
},
"statistics": {
"cpu_freq": {
"min": 2.29,
"avg": 2.29,
"max": 2.29
}
},
"stacking_multicast": "229.245.235.211",
"stacking_port": "65513",
"cloud_license": "TjJTjL0H0XCNoHQXJQFCA8qGcFOHCU0PYO8BwesR",
"license_server_host": "lic.srvc.tagvs.com",
"disable_http_access": "0",
"disable_ftp_access": "0",
"disable_ftps_access": "0",
"nmos_settings": "registry=1.1.1.1:1111",
"ndi_discovery_servers": null,
"ssh_admin_password": null,
"nielsen_monitoring_license": null
}
} |
|
The “next_boot_image” id is needed in step 4 to select the right image to be upgraded.
...
4.
...
Set next boot image from the dropdown
...
Anchor |
---|
| step4 |
---|
| step4 |
---|
isMissingRequiredParameters | true |
---|
|
...
By default the current image is choosen in the dropdown list of the Next Boot Image. To choose the latest image uploaded use the image_id. Here, the latest image to be upgraded is the Image-2 | firmware:1.1.8 software:6.3.7. Hence, image_id = 2.(image_id is the id from next_boot_image in step 3)
Use the following command to choose the image from the drop down list.
GET Resource URL : http://{host}/api/2.0/devices/switchBootImage/2{image_id}/.json
Please refer to API documentation here.
For example, http://192.168.10.131/api/2.0/devices/switchBootImage/2/.json
Response |
Code Block |
---|
| {
"Task": {
"id": 355905,
"device_id": 9898,
"type": "Switch Boot Image",
"type_id": 4,
"mode": "Starting",
"mode_id": 1,
"status": null,
"description": null,
"total": 0,
"completed": 0,
"time_remained": 0,
"modified": "1704971865885"
}
} |
|
5. Finally reboot the
...
System
Anchor |
---|
| step5 |
---|
| step5 |
---|
isMissingRequiredParameters | true |
---|
|
Use the following command to reboot the System.
GET Resource URL : http://{host}/api/2.0/devices/command/hardReset/.json
Please refer to API documentation here.
For example, http://192.168.10.131/api/2.0/devices/command/hardReset/.json
Expand |
---|
|
Code Block |
---|
| {
"Task": {
"id": 513196,
"device_id": 9898,
"type": "System Reboot",
"type_id": 10,
"mode": "Starting",
"mode_id": 1,
"status": null,
"description": null,
"total": 0,
"completed": 0,
"time_remained": 0,
"modified": "1704974942974"
}
} |
|