Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

IDNameEvent ErrorDescription

200

AES3 Word Size Match

AES3 Word Size Mismatch

AES3 can be combined for 16, 20, and 24-bit samples or 20, 24, and 32-bit samples, which are configured on the channel configuration and being matched in air. The current value is compared with the expected value.

The event will trigger when the detected word size does not match the configured AES3 word size.

201

Dolby-E Frame Counter Gap

Dolby-E Frame Drop

Dolby-E is a compressed Dolby which is transmitted through the AES3. Each Dolby frame has a counter that increments for every frame, and if the value is hopped by one or more, then the event Gap detected on Dolby-E frame count will trigger.

202

Dolby-E Frame Header CRC Error

Dolby-E CRC Error

CRC error on Dolby-E frame header. Dolby-E is not decoded.

203

Dolby-E Line Position Warning (us from ideal 800us)

Dolby-E LinePos

The Dolby-E starting line position is 800us. The event will trigger if the detected Dolby-E Line Position does not match the configuration. This event is only a warning!

204

Dolby-E line Position Fault (DVB: 450-1860us, ATSC: 510-1400us)

Dolby-E LinePos Error

Dolby-E Line Position does not match the standard (DVB: 450-1860us, ATSC: 510-1400us). The event is triggered when the Line Position is outside the standard.

205

Verify Dolby-E Frame Rate Match

Dolby-E Framerate Error

The event will trigger when the Dolby-E frame rate does not match the video frame rate.

206

AES3 PES Drop - AES3 PTS/DTS and PCR Mismatch

AES3 PES Drop

AES3 PTS/DTS mismatch concerning PCR. DTS/PTS in AES3 PES is too late or early in comparison to PCR.

  • No labels