The MCM9000 is a state-of-the-art software solution and is constantly being developed and improved.
...
- Download the file from TagVS Storage Center.
- MCM9000; System → Software management → Upload Software File
- Browse for the previously downloaded file and upload the *.rar file (without extracting the file)
- Select "Submit "
...
4. Set the next boot with the new software file; System → Software management
- Boot Image Selection
- Change the next Boot Image to the new file version
- Submit
5. Rollback – The MCM9000 holds 2 software versions at all timetimes.
In case the MCM9000 has an upgrade failure or a critical bug in the current version, there is always the option of rolling back to the previous version.
In order to rollback, simply follow again the steps as described in previous step #4 (above) and change the next Boot Image to be the previous file version → Submit→ Submit, continue to step steps 6,7,8 (Next page).
6. Save configuration
7. Reboot the System; System → Device Control → Reboot
8
8. Verify the version on the main page or; System → Device Information → Version