Hardware Target
This document specifies handling the overheating for the DELL PowerEdge R640 server.
Prerequisites
Download BIOS firmware from the DELL site and save it locally.
https://www.dell.com/support/home/il/en/ilbsdt1/product-support/product/poweredge-r640/drivers
Entering the iDRAC GUI
Connect a cable to the iDRAC port on the back of the server.
Power on or reboot the system. When a splash screen appears (the screen with the logo) press the F2 key to enter BIOS setup.
Select “iDRAC Settings” and then “Network”.
Follow screenshot for configuration. Enter your own IP address.
Click “Back” and scroll down to enter “User Configuration”.
Set a user name and password.
Click “Back” and “Finish” twice to exit configuration and restart the server.
On a workstation in the network, open a browser and type the IP you entered for the IPv4 settings.
Type the user name and password as set in the previous step.
Update the BIOS
Go to “Maintenance” → “System Update” and browse for the BIOS file you downloaded.
Check the box and click “Install and Reboot”.
This will take some time.
Setting Fan Speed
If updating the BIOS wasn’t enough, you should try increasing fan speed.
Go to “Configuration” → “System Settings” → “Hardware Settings” and set as seen in the following screenshot.
Reset to Default