Table Parameters in the Threshold Sets
The Threshold Sets GUI consists of 22 Tabs. Each tab is made of tables indicating several events. A detailed description of these events is explained in the Event Code. Each table in the Threshold Sets is made of the below parameters.
Parameters | Description |
ID | It is a unique value given for different events in the Threshold Sets. |
Name | Name of the events. |
Standard | It is the appropriate international standard for the event. |
Threshold | Triggers an alarm to notify the user when an event does not occur at the specified threshold range. The threshold units can be CC/sec, ms, min, etc., depending on the event. |
Severity | The alarms are classified based on the severity as Critical, Major, Minor, Warning, Notice, Info. Abnormalities in the Event could cause:
|
Record | All events can trigger a short recording clip of the channel input stream at the time it occurred, which can be used for investigating the cause in the event history. To activate a trigger, click the check icon () in the Record column to select the toggle buttons . |
Default | As mentioned in the previous section, a new set is created to replicate the default set. |
Once the configurations are done, click the submit changes button to save the changes. If not, the changes will not be saved.
As all threshold sets are based on the default one, any change to the default set will be applied to all configured sets, excluding errors configured to override the default.